Saint Gobain Oberland AG

AGO constructed a plant for high-pressure steam generation using exhaust gases from a glass melting tank, with feedwater degassing and water treatment.

Hot water is generated using a natural gas-fired large-water-tube boiler. The heat is transferred to a district heating network with pressure maintenance and district heating pumps.

 

Technical data:

  • Thermal output: 16.8 MW
  • Steam generation: 4.8 t/h, 19.5 bar